Distribution Transformers​

Dry Type Distribution Tranformer

Dynamic’s VPI Dry Type Transformers are vacuum pressure impregnated with a high temperature polyester varnish. The process includes complete submersion in varnish under vacuum and pressure and regulated curing through PLC controlled equipment to ensure consistency. The finished coils are effectively protected against moisture , dirt and most industrial contaminants.
High Class H rated insulation products such as Nomex, Kapton and Glass Tape etc are used for the insulating materials . The design and construction of the windings together with the VPI treatment of the winding ensures that it is electrically sound as well as mechanically strong resulting in reduction of risk of explosion or danger of fire. The consumers prefer these Transformers for use in Basements or Stilts of High Rise Buildings, Hospitals, Hotels and Shopping Malls etc.
Dynamic’s Dry Transformers are enclosed in sheet steel enclosure and are totally maintenance free .These are Eco friendly Transformers there is no oil used in it, hence no chances of oil leakage or spillage.
These Transformers are pocket friendly too apart from being Eco friendly as the windings in these VPI Transformers can be removed and repaired which is not feasible in case of Cast Resin Transformers.
Dynamic’s manufacturing range of Dry Type Transformers is up to 2500 KVA rating & 11KV class With Off Circuit Tap Links ( OCTL) as well as On Load Tap Changer ( OLTC )
 

 

Oil Cool Distribution Transformer

Dynamic covers a wide range of oil cooled distribution transformers with Off Circuit tap changer as well as with On load Tap changer ( upto 5000 KVA capacity in 11KV, 22Kv & 33Kv class).
Magnetic Circuit of the Transformer is made by assembling high grade Cold rolled grain Oriented Silicon laminations having high permeability and low hysteresis loss. HV and LV windings are made in shape of coils, perfectly circular, with electrolytic grade Copper /Alumium conductor ( as per client’s demand. These coils are dried and pressed to pre-determined stack heights, assembled concentrically on the core and magnetically balanced with respect to each other, thus minimizing mechanical stresses.
Core & Coil Assembly is clamped by clamping structure and is dried for a specified heating cycle, under controlled temperature to drive away any moisture. After drying, the assembly is put inside the prefabricated tank, clamped and filled with filtered, dehydrated Transformer oil. All electrical Connections are made and complete set of fillits and reuired accessoties are fitted. The Transformer after painting becomes ready for testing.
  • Rating & Diagram Plate
  • Earthing Terminals
  • Lifting Lugs
  • Oil Level Indicator
  • Pressed Steel Radiators
  • Drain Cum Bottom Filter Valve
  • Oil Conservator With Drain Plug
  • Oil Filling Holewith Plug On Conservator
  • Double Diaphragm Explosion Vent
  • Pressure Relief Valave
  • Air Release Plug
  • Silica Gel Breather
  • Uni-Directional Rollers
  • Externally Operated Off Circuit Tap Changing Swithch
  • First Filling Oil

 

  • Oil Temperature Indicator With Alarm & Trip Contacts
  • Winding Temperature Indicator With Alarm & Trip Contacts
  • Buchholz Relay With Alarm & Trip Contacts
  • Lv And /Or Hv Cable Box
  • Pressure Relief Valve With Trip Contact
  • Magnetic Oil Level Gauge With Alarm Contact
  • Marshalling Box
  • On Load Tap Changer ( Oltc)
  • Rtcc Panel
  • Bus Duct Chamber On Lv Side
  • Disconnecting Chamber On Hv Side
  • Jacking Pads & Pulling Eyes